Determination of paroxetine levels in human plasma using gas chromatography with electron-capture detection

C T Lai1, E S Gordon, S H Kennedy

  • 1Department of Psychiatry, Mackenzie Health Sciences Centre, University of Alberta, Edmonton, Canada. ctlai@gpu.srv.ualberta.ca

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance01:23

Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance

The elimination half-life and drug clearance of drugs following nonlinear kinetics can vary with dosage. The Michaelis-Menten parameters and drug concentration influence these factors. As the dose increases, the elimination half-life tends to lengthen, resulting in a reduction in clearance and a disproportionately larger area under the curve. The total clearance can be derived from the Michaelis-Menten equation for drugs following a one-compartment model.
A study on guinea pigs examined the...