October 18, 2000 8:30-8:45. Problem Solving with FDG Positron Emission Mammography
Abstract:
Purpose: To examine one potential clinical application of dedicated devices for positron emission mammography.Background: Dedicated devices for breast imaging with FDG have technical specifications that appear well-suited for detecting small breast cancers, including registration with x-rays, high count sensitivity, and spatial resolution in the 2-3 mm range.Methods: In IRB-approved clinical trials, patients who were scheduled for biopsy for suspicious findings on x-ray mammograms were injected with 10-20 mCi FDG intravenously one to two hours prior to x-ray guided core biopsy or lumpectomy. Positron emission mammograms using a dedicated device were performed just before biopsy, and results compared to final histopathology.Results: Three patients whose cancers were missed on initial x-ray mammograms or whose mammograms contained subtle abnormalities that were not strongly suspicious for cancer, were shown to have very suspicious hot spots on positron emission mammograms. These patients were later confirmed to have cancer.Discussion: The role for dedicated devices for positron emission mammography is evolving. Finding cancers that are either mammographically occult or have low indices of suspicion is a potential application for this technique. Further clinical and technical work will be needed to better define the strengths and weaknesses of the device in this application.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET