Related Experiment Video
Updated: Jul 11, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Determination of ambulatory blood pressure control in treated patients with controlled office blood pressures
M D Wilson1, J J Barron, K A Johnson
1Health Core, Inc., Newark, DE 19713, USA. mwilson@healthcore.com
Abstract:
Office blood pressure measurement is the standard for assessing blood pressure control. Many patients, however, take their antihypertensive medication in the morning, so they are likely to have their office blood pressure measured during the maximal antihypertensive effect. It is therefore unknown whether patients deemed by office blood pressure to be controlled do in fact have 24h blood pressure control. The objectives of this study were to determine blood pressure control, including blood pressure control while the patients were awake and during the first 6 hours after awakening, by ambulatory blood pressure monitoring (ABPM) in treated hypertensive patients deemed by office blood pressure measurements to be controlled. A total of 103 patients on a stable antihypertensive regimen and deemed to be controlled in terms of office blood pressure values (mean office blood pressure <140/90mmHg) were enrolled. Patients were stratified by cardiovascular risk status and the number of antihypertensive medications that they were taking. Seventy-eight out of 103 participants successfully completed ABPM. The mean ambulatory blood pressure was greater than 135/85mmHg and 140/90mmHg while awake for 37% (95% confidence interval [CI] 26-48%) and 23% (95% CI 14-32%) of all patients respectively. Forty-eight per cent (95% CI 33-63%) of patients taking monotherapy versus 25% (95% CI 11-39%) of patients on multiple antihypertensive medications were uncontrolled (P=0.039) using 135/85mmHg as the reference value. Thirty-one per cent (95% CI, 17-44%) of patients on monotherapy versus 14% (95% CI 3-25%) of patients on multiple antihypertensive medication were uncontrolled (P=0.064) using 140/90mmHg instead. These results demonstrate that a high number of patients deemed by office blood pressure to be under control do not have adequate blood pressure control based on ABPM.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure

