Related Experiment Video
Updated: Jul 30, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Spiral CT colonography: reader agreement and diagnostic performance with two- and three-dimensional image-display
E G McFarland1, J A Brink, T K Pilgram
1Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110, USA. mcfarlandb@mir.wustl.edu
Purpose:
To assess the diagnostic performance and reader agreement with two-dimensional (2D) and three-dimensional (3D) display techniques for detecting colorectal polyps with spiral computed tomographic (CT) colonography.
Materials And Methods:
A test set of 30 colonic segments was developed from spiral CT colonographic studies (12 with polyps and 18 without). The 12 segments with polyps contained 22 lesions (11 polyps <10 mm, 11 polyps or cancers >/=10 mm), with all findings verified with colonoscopy. Three specific 2D and 3D image-display techniques were tested. Three experienced abdominal radiologists independently analyzed each test case and were retested 6 weeks later.
Results:
The results of readings 1 and 2 were similar for all image-display techniques among the readers. Pooled segment results were sensitivity of 89%-92% and specificity of 72%-83%. Pooled polyp size results for sensitivity and positive predictive value were 77%-86% and 74%-86% (all polyps, n = 22), 91%-100% and 85%-100% (polyps or cancers >10 mm, n = 11), and 61%-73% and 61%-80% (polyps 5-9 mm, n = 11), respectively. Overall intraobserver agreement was good for the three display techniques (kappa, 0.60-1.00); however, interobserver agreement for 2D multiplanar reformation was lower (kappa, 0.53-0.80).
Conclusion:
Among experienced abdominal radiologists, similar diagnostic performance in polyp detection was found among 2D multiplanar reformation and 3D display techniques, although individual cases showed improved characterization with 3D display techniques. Evaluation of reader agreement demonstrated good intraobserver agreement, with variable interobserver agreement.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography