Related Experiment Video
Updated: Aug 10, 2026
![Visualization and Quantification of Brown and Beige Adipose Tissues in Mice using [18F]FDG Micro-PET/MR Imaging](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62460.jpg&w=3840&q=50)
Visualization and Quantification of Brown and Beige Adipose Tissues in Mice using [18F]FDG Micro-PET/MR Imaging
Published on: July 1, 2021
Can non-shivering thermogenesis in brown adipose tissue following NA injection be quantified by changes in overlying
D M. Jackson1, C Hambly, P Trayhurn
1Department of Zoology, Aberdeen Centre for Energy Regulation and Obesity (ACERO) University of Aberdeen, AB24 2TZ, Scotland, UK
Abstract:
We aimed to investigate whether infra red thermography (IRT) can be used to measure and quantify non-shivering thermogenesis (NST) in the short-tailed field vole Microtus agrestis, by directly comparing it with a standard method, i.e. metabolic response following Noradrenaline injection (NA). Mean skin surface temperature overlying Brown adipose tissue (BAT) depot was 0.82 degrees C higher than mean surface temperature that did not overly BAT. The difference in temperature increased by 1.26 degrees C after NA was administered. Mean skin surface temperature overlying BAT increased by 0.32 degrees C after NA was administered; however, surface temperature decreased by 1.32 degrees C after saline was administered. Mean skin surface temperature overlying BAT did not change significantly between warm and cold acclimated voles; in contrast metabolic peak following NA injection significantly increased in cold acclimated voles. There was no significant correlation between change in surface temperature after NA injection and metabolic peak following NA injection. The results of this study suggest that IRT is not a sensitive enough method to measure changes in NST capacity in BAT following NA injection, or to detect changes in NST capacity induced by cold acclimation. However, IRT can distinguish between skin surfaces overlying BAT and skin surfaces that do not.
More Related Videos
Related Concept Videos
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

