Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Triangular transchamber suture.

M S Seo1, H J Nah, K J Yang

  • 1Department of Ophthalmology, Chonnam National University Medical School and Hospital, Chonnam National University Research Institute of Medical Sciences, Kwangju, South Korea. msseo@chonnam.ac.kr

Journal of Cataract and Refractive Surgery
|February 13, 2001
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Effect and mechanism of taurocholic acid in promoting colorectal cancer liver metastasis by regulating neutrophil extracellular trap formation].

Zhonghua yi xue za zhi·2026
Same author

Biomechanical comparison of bone staple fixation methods with suture material for median sternotomy closure using 3D-printed bone models.

New Zealand veterinary journal·2024
Same author

Validation of a Korean version of the quality-of-life profile for spine deformities (QLPSD) in patients with adolescent idiopathic scoliosis.

European review for medical and pharmacological sciences·2022
Same author

Association between smoking and Behçet's disease: a nationwide population-based study in Korea.

Journal of the European Academy of Dermatology and Venereology : JEADV·2019
Same author

Differential expression of programmed death-1 according to the histological differentiation of cutaneous squamous cell carcinoma.

The British journal of dermatology·2019
Same author

Large-scale growth and taxane production in cell cultures of Taxus cuspidata (Japanese yew) using a novel bioreactor.

Plant cell reports·2019
Same journal

Light adjustable lens implantation with cataract surgery in eyes with macular pathology.

Journal of cataract and refractive surgery·2026
Same journal

Comment on: Use of intracameral antibiotics prophylaxis in patients with posterior capsule rupture during cataract surgery: systemic review and meta-analysis.

Journal of cataract and refractive surgery·2026
Same journal

Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).

Journal of cataract and refractive surgery·2026
Same journal

Multimodal Deep Learning for Predicting Postoperative Vault and Selecting ICL Sizes Using AS-OCT and UBM Images.

Journal of cataract and refractive surgery·2026
Same journal

Reply: Evaluating large language models vs residents in cataract and refractive surgery: comparative analysis using the American Academy of Ophthalmology Self-Assessment Program.

Journal of cataract and refractive surgery·2026
Same journal

Comment on: Evaluating large language models vs residents in cataract and refractive surgery: comparative analysis using the American Academy of Ophthalmology Self-Assessment Program.

Journal of cataract and refractive surgery·2026
See all related articles

This report describes a surgical technique using a specialized suture pattern to secure an artificial lens in a patient who lost their iris due to injury. By creating a stable support structure, the procedure prevents the lens from touching the cornea and maintains clear vision over several years.

Area of Science:

  • Ophthalmology surgical techniques within ocular trauma management
  • Triangular transchamber suture applications in reconstructive eye surgery

Background:

Ocular trauma often results in severe structural damage that complicates standard lens replacement procedures. Surgeons frequently encounter challenges when the iris is absent and fibrous tissue forms behind the pupil. Existing methods for securing artificial lenses may fail to provide adequate long-term stability in these complex anatomical environments. This uncertainty drove the exploration of novel fixation strategies to prevent dangerous contact between the implant and the cornea. No prior work had resolved the difficulty of maintaining lens positioning in eyes with massive hemorrhage and extensive tissue loss. Traditional approaches often lack the necessary support to keep the lens centered over time. This gap motivated the development of a specialized suturing technique to address these specific anatomical deficiencies. The current report evaluates the effectiveness of this approach in a patient who suffered significant ocular injury.

Purpose Of The Study:

The aim of this report is to describe a specialized surgical technique for stabilizing an artificial lens in patients with severe iris loss. The authors address the specific challenge of preventing contact between the lens and the cornea after traumatic injury. This problem often arises when traditional support structures are absent, leading to potential complications. The motivation for this work stems from the need to improve long-term outcomes in complex ocular reconstructions. The researchers sought to demonstrate how a triangular suturing pattern provides the necessary stability for the implant. They focused on a case involving a patient who suffered from massive intraocular hemorrhage and fibrous membrane formation. By documenting this approach, the study provides a potential solution for surgeons facing similar anatomical limitations. The work highlights the importance of innovative fixation methods in restoring vision after significant ocular trauma.

Keywords:
intraocular lens implantationiris loss reconstructioncorneal protectionsurgical fixation techniques

Frequently Asked Questions

The researchers propose that the triangular configuration creates a stable barrier, preventing the artificial lens from shifting forward. This mechanical support ensures the implant remains separated from the corneal endothelium, thereby avoiding potential damage to the ocular surface while maintaining consistent visual clarity for the patient.

The authors utilized a posterior chamber intraocular lens, which serves as the primary prosthetic device. This specific implant type is designed to replace the natural lens, providing necessary refractive power when the original structures are compromised due to severe trauma or tissue loss.

The authors state that the fibrous membrane at the lens plane is necessary to provide a base for the implant. This tissue layer allows the surgeon to position the artificial lens securely, which would otherwise be impossible without the support of a natural iris structure.

Related Experiment Videos

Main Methods:

The surgical team performed a detailed assessment of a patient presenting with severe ocular trauma and iris loss. Their review approach involved the implantation of a posterior chamber intraocular lens placed anterior to an existing fibrous membrane. The surgeons executed a triangular suturing pattern to anchor the device firmly within the eye. This design aimed to isolate the implant from the corneal surface to prevent mechanical damage. The clinical team monitored the patient over a three-year period to evaluate the stability of the lens. They assessed visual rehabilitation outcomes through standard ophthalmological examinations during follow-up visits. The methodology focused on documenting the long-term positioning of the prosthetic device in the absence of natural iris support. This observational strategy allowed for the verification of the technique's effectiveness in a complex clinical setting.

Main Results:

The strongest finding from the literature indicates that the artificial lens remained in a stable position three years after the procedure. The patient achieved satisfactory visual rehabilitation throughout the entire follow-up duration. The report confirms that the surgical intervention occurred without any subsequent complications. The authors observed that the lens successfully maintained its intended orientation despite the initial massive intraocular hemorrhage. The triangular configuration effectively prevented any contact between the implant and the cornea. This outcome demonstrates the reliability of the suturing method in cases involving extensive structural damage. The data show that the patient experienced no adverse events related to the lens placement during the observation period. The findings highlight the successful restoration of function in an eye that had previously lost all iris tissue.

Conclusions:

The authors propose that this specific suturing pattern provides reliable long-term stability for artificial lenses in challenging cases. Their findings suggest that the technique effectively prevents contact between the implant and the delicate corneal surface. The report demonstrates that visual outcomes remain positive for several years following the initial intervention. This synthesis indicates that the method is a viable option for patients lacking iris support. The authors emphasize that the procedure maintains the lens in a favorable position without secondary complications. Their review of the case supports the utility of this approach in reconstructive ocular surgery. The evidence implies that the triangular configuration offers a robust solution for complex lens fixation needs. This clinical observation provides a foundation for considering such techniques in similar traumatic injury scenarios.

The authors report that the suture acts as a structural anchor. This component is essential for maintaining the orientation of the implant, ensuring it does not migrate or tilt within the eye following the surgical correction of the traumatic injury.

The researchers observed that the lens remained in a stable position for three years. This measurement confirms the long-term efficacy of the intervention, as the patient experienced satisfactory visual rehabilitation without any signs of late-stage complications or adverse tissue reactions.

The authors suggest that this technique is a reliable solution for patients who have experienced traumatic loss of the iris. They propose that this approach should be considered when standard implantation methods are insufficient to ensure the safety and positioning of the artificial lens.