Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Estimation of body water compartments in cirrhosis by multiple-frequency bioelectrical-impedance analysis
M E Lehnert1, D D Clarke, J G Gibbons
1Department of Gastroenterology and Hepatology, Princess Alexandra Hospital, Ipswich Road, Wooloongabba, Queensland 4102, Australia.
Abstract:
Estimation of total body water by measuring bioelectrical impedance at a fixed frequency of 50 kHz is useful in assessing body composition in healthy populations. However, in cirrhosis, the distribution of total body water between the extracellular and intracellular compartments is of greater clinical importance. We report an evaluation of a new multiple-frequency bioelectrical-impedance analysis technique (MFBIA) that may quantify the distribution of total body water in cirrhosis. In 21 cirrhotic patients and 21 healthy control subjects, impedance to the flow of current was measured at frequencies ranging from 4 to 1012 kHz. These measurements were used to estimate body water compartments and then compared with total body water and extracellular water determined by isotope methodology. In cirrhotic patients, extracellular water and total body water (as determined by isotope methods) were well predicted by MFBIA (r = 0.73 and 0.89, respectively). However, the 95% confidence intervals of the limits of agreement between MFBIA and the isotope methods were +/-14% and +/-9% for cirrhotics (extracellular water and total body water, respectively) and +/-9% and +/-9% for cirrhotics without ascites. The 95% confidence intervals estimated from the control group were +/-10% and +/-5% for extracellular water and total body water, respectively. Thus, despite strong correlations between MFBIA and isotope measurements, the relatively large limits of agreement with accepted techniques suggest that the MFBIA technique requires further refinement before it can be routinely used to determine the nutritional assessment of individual cirrhotic patients.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:05Clinical Application of Phase Angle and BIVA Z-Score Analyses in Patients Admitted to an Emergency Department with Acute Heart Failure
Published on: June 30, 2023
Related Concept Videos
Bode Plots Construction
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):