Related Experiment Video
Updated: Aug 9, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Organ radiation dose assessment for conventional spiral tomography: a human cadaver study
C Bou Serhal1, D van Steenberghe, H Bosmans
1Department of Periodontology, Oral Imaging Cluster, Faculty of Medicine, Catholic University of Leuven, Kapucijnenvoer 7, 3000 Leuven, Belgium.
Abstract:
The head of a human cadaver was positioned in a Cranex TOME multifunctional unit (Orion Corporation Soredex, Helsinki, Finland) to measure the organ radiation doses after tomographic examinations of the upper and lower edentulous jaw bone. Five consecutive examinations were carried out in the upper and lower anterior jaw regions to cover the entire frontal area, 2 in the upper and lower left premolar regions, and 3 and 4 in the upper and lower left molar regions, respectively. Each examination consisted of 4 slices with a 2 mm slice thickness. Thermoluminescent dosimeter chips were placed in the thyroid gland and bilaterally in the parotid and submandibular glands. Dosimetric measurements were repeated for the different tomographic examinations mentioned above. For spiral tomography in the maxilla, organ doses for both parotid glands were most elevated, while those for the thyroid glands were the lowest. Average doses per examination reached levels of 0.27 mGy for the right (OS) parotid gland with frontal tomography, and 3.89 mGy and 1.67 mGy for the parotid gland at tube-side (TS) for premolar and molar tomography. For the thyroid gland, a minimal dose of < or = 0.004 mGy was noticed for all examinations. For spiral tomography of the frontal area in the mandible, the OS parotid gland received the highest dose (0.77 mGy), while for an analysis of the premolar and molar areas, doses were more elevated for the TS parotid gland (1.22 mGy and 1.72 mGy, respectively). For the TS submandibular gland, organ doses were also raised, with values of 0.39 mGy for frontal, 1.31 mGy for premolar and 1.61 mGy for molar tomography. This study thus indicates that for conventional spiral tomographic examinations in the maxilla and the mandible, radiation doses for the TS submandibular and parotid glands were significantly more elevated than those to the thyroid gland. These values remain however below the organ doses previously reported for spiral CT involving both a full upper or lower jaw.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET