Related Experiment Video
Updated: Oct 9, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Pitfalls in endoscope reprocessing: brushing of air and water channels is mandatory for high-level disinfection
Background:
Endoscopic transmission of pathogens has been reported. Guidelines have been formulated concerning the risk of infection via contaminated suction and accessory channels. Contamination of the other 2 channels for air and water has not been demonstrated. These channels were examined to clarify whether they require cleaning.
Methods:
Endoscopes used for examinations were divided into 2 groups. Group A endoscopes (n = 20) were brushed along the air and water channels. Group B endoscopes (n = 22) were not. After machine reprocessing, specimens were obtained for bacterial culture. The residual protein was measured in the 2 channels by using amido black 10B dye, and results were compared between the 2 groups.
Results:
With regard to the air channel, there were no contaminated endoscopes detected in either group. For the water channel, 1 endoscope in group B was positive whereas there were none positive in group A. With regard to quantification of residual protein, brushing diminished the level in both the air and the water channels.
Conclusion:
The air and water channels can become contaminated. Brushing every channel is mandatory for high-level disinfection. A redesign of the fundamental structure of endoscopes is proposed.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hand hygiene
Hand washing...
Handwashing III: During the Procedure and Post-Procedure Steps
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail paint...