Related Experiment Video
Updated: Aug 18, 2026

Whole-mount Clearing and Staining of Arabidopsis Flower Organs and Siliques
Published on: April 12, 2018
Sodium thiosulfate solution spray for relief of irritation caused by Lugol's stain in chromoendoscopy
1Department of Endoscopy and Gastrointestinal Oncology, National Cancer Center Hospital, Tokyo, Japan.
Background:
Mucosal iodine staining is known to improve the endoscopic visualization of esophageal squamous dysplasia and cancer. However, it often causes mucosal irritation leading to retrosternal discomfort. The clinical usefulness of sodium thiosulfate solution (STS) for easing symptoms induced by mucosal staining with Lugol's solution was evaluated in this study.
Methods:
One hundred twenty healthy men over 50 years of age were enrolled in the study. They each underwent esophagogastroscopy including the spraying of Lugol's iodine solution (10 mL) on the mid and distal esophagus and were subsequently randomized into three groups: (I) no treatment (n = 40), (II) spraying of 20 mL of aluminum-magnesium hydroxide gel (Maalox) by means of endoscopic catheter (n = 40), and (III) spraying of 20 mL of 5% sodium thiosulfate solution by means of endoscopic catheter (n = 40). An hour after the endoscopic examination the subjects were asked to complete a questionnaire that addressed adverse symptoms induced by Lugol's iodine staining.
Results:
Sodium thiosulfate solution spray substantially reduced adverse symptoms that lasted more than 30 minutes after chromoendoscopy, compared with the no-treatment group. There was no significant difference in the proportion of subjects with symptoms between the Maalox and no-treatment groups. Cost of sodium thiosulfate solution spray per use was $0.15 (15 yen).
Conclusions:
Sodium thiosulfate solution is recommended for routine use after Lugol's staining.
Related Concept Videos
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Redox Titration: Other Oxidizing and Reducing Agents
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Simple Staining Technique
Special Staining Techniques

