Related Experiment Video
Updated: Oct 9, 2026

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
Reproducibility of QT parameters derived from 24-hour ambulatory ECG recordings in healthy subjects
H Arildsen1, E H Christiansen, A K Pedersen
1Department of Cardiology (Research unit), Skejby University Hospital, DK-8200 Aarhus N, Denmark. arildsen@dadlnet.dk
Aim:
To estimate the reproducibility of QT parameters derived from 24-hour ambulatory ECG recordings.
Method:
Ten healthy volunteers aged 25 to 41 years participated. In two 24-hour ambulatory ECG recordings obtained 1 day apart, the QT interval was measured manually at stable heart rates in approximately 16 periods during daytime and 6 periods during nighttime. The association between the QT and RR interval was described by linear regression for day and nighttime separately and the following QT parameters were calculated: the QT interval at heart rate 60 beats/min during daytime (QT(60)day), slope(day), slope(night), and the difference in QT(60) between day and nighttime (DeltaQT(60)). The QT parameters were assessed four times for each participant to discriminate method inaccuracy from day to day variation. The reproducibility was estimated as the coefficient of repeatability, the relative error, and the ratio between within-subject variability and between-subject variability.
Results:
The coefficient of repeatability, the relative error and the ratio, respectively, were 19 ms, 1.8% and 0.5 for QT(60)day, 0.076, 21% and 0.68 for slope(day), 0.116, 43% and 1.37 for slope(night), and 37 ms, 325% and 1.19 for DeltaQT(60) when estimating the overall day to day reproducibility. Inaccuracy of QT measurement accounted for approximately 40% of this variation, whereas the error caused by selecting segments was small.
Conclusion:
QT(60)day has a high reproducibility and may with advantage replace the conventional QT interval measured on a resting ECG. To assess QT dynamics, the slope of the regression line during daytime is suitable and the short term reproducibility acceptable for clinical trials. Regarding slope(night) and DeltaQT(60), the variation is high and the parameters should be used with caution.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Holter Monitor: 24-Hour Monitoring
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...