Related Experiment Video
Updated: Dec 29, 2025

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Interobserver Variability of Left Ventricular Measurements in a Population of Predominantly Obese Hypertensives Using
Jeffrey S. Jhang1, Joseph A. Diamond, Robert A. Phillips
1Mount Sinai School of Medicine, Hypertension Section, Box 1085, One Gustave L. Levy Place, New York, NY 10029-6574.
Abstract:
Achieving low interobserver variability is a goal of echocardiographic determined left ventricular (LV) mass measurements. In a group of hypertensives, we evaluated interobserver variation using a method of simultaneously acquired two-dimensional (2-D) cine and M-mode images displayed in a split screen format. Sixty echocardiographic images from ongoing hypertension trials, including serial studies of the same patients, were obtained with an UltraMarktrade mark 6 Ultrasound System (Advanced Technology Laboratories, Inc., Bothell, WA, USA). Images were digitized online, coded with a random number, and pooled prior to the analysis to minimize observer bias. Studies were read by two independent observers in a blinded fashion and in a random order using a Color Vue II Nova MicroSonicstrade mark analyzer (Nova Microsonics, Mahwah, NJ, USA). The M-mode tracing and cine of three consecutive frames of 2-D parasternal short-axis views of the LV were simultaneously displayed in a split screen format. The 2-D cine was used as a reference image during M-mode measurements of LV dimensions. Measurements were obtained and the LV mass estimated according to the Penn convention. Interobserver variability for left ventricular internal dimension (LVID), interventricular septal thickness (IVS), posterior wall thickness (PWT), and left ventricular mass (LV mass) is low when either correlated (Pearson correlation coefficients of 0.94, 0.82, 0.75, and 0.93, respectively) or expressed as a percent of the mean (3.0%, 10.0%, 10.2%, and 8.9%, respectively). When read in a blinded fashion, interobserver variability (especially for LV mass) is small using digitized, simultaneously acquired and displayed cines of 2-D and M-mode echocardiograms. This is likely due to the ability to discriminate myocardial wall edges (endocardium) from other associated structures such as tricuspid and mitral apparatus. This method may prove useful in studies of LV mass.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)