Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Catheters for tracheal gas insufflation
1Regions Hospital, Pulmonary Research Laboratory, 640 Jackson Street, St. Paul MN 55101-2595, USA. Alex.B.Adams@healthpartners.com
Abstract:
As an adjunct to mechanical ventilation, tracheal gas insufflation (TGI) injects gas flow into the trachea to flush carbon dioxide (CO2) from the anatomical and mechanical dead space, but the addition of TGI flow from a catheter may cause problems related to increased flow velocity at the catheter tip. Forward momentum and turbulence beyond the tip oppose expiratory flow and may cause or increase intrinsic positive end-expiratory pressure. If the catheter is placed within the endotracheal tube (ETT), the catheter itself acts as a resistive element to exhalation. Effects of the catheter presence (contact on or whipping against the airway) or local rapid gas flow effects on the tracheal mucosa are possible. Thus far, TGI has been delivered through a range of catheter sizes and styles. Two general design modifications have been incorporated in TGI systems to address the possible problems: embedding the catheter flow channel within the ETT, and directing the TGI flow cephalad. The LaBrune-Boussignac tube was designed with 6 or 8 channels embedded within the ETT, from which TGI flow exits laterally within the ETT at 1.5 cm from its tip. This avoids the use of a catheter and thus avoids local traumatic effects. A reverse-thrust catheter has been designed to direct flow within a sheath around the catheter tip; flow exits cephalad from a gap between the sheath and the catheter shaft. As part of a proposed ventilatory mode (intratracheal pulmonary ventilation) the reverse-thrust catheter delivers the tidal breath and, additionally, flushes CO2 and accelerates secretion removal during exhalation. A reverse-flow design ETT has been developed with two channels, one for tidal volume delivery and the other for TGI flow. The TGI channel is relatively large and flow is directed cephalad by a nozzle at the catheter tip. A recently developed bidirectional catheter allows the option of delivering TGI flow cephalad, towards the lungs or in both directions. Unfortunately, to be convenient, the use of specially designed catheters or ETTs requires the anticipation of TGI use. A complete system for the safe and convenient use of TGI in ventilated patients is not as yet available, but concerns about the safety and convenience of TGI delivery have been addressed with recent advances in catheter/tube design.
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: