Thrombectomy with the X-SIZER catheter system in the coronary circulation: initial results from a multi-center study

T Ischinger1,

  • 1Division of Cardiology, Klinikum Munchen-Bogenhausen, 81925 Munchen, Germany. Thomas.Ischinger@extern.lrz-munchen.de

Insights

The X-SIZER catheter effectively removes intracoronary thrombus in suitable vessels, improving blood flow and reducing stenosis safely. This novel device offers a promising solution for challenging thrombotic lesions in coronary interventions.

Area of Science:

  • Interventional Cardiology
  • Medical Device Technology
  • Vascular Surgery

Background:

  • Intracoronary thrombus poses significant challenges in catheter-based interventions, often leading to incomplete lesion treatment and distal embolization.
  • Existing treatments like lytics, antiplatelet agents, stents, and thrombectomy devices have limitations in thrombus reduction and embolization risk.
  • A novel device is needed to safely and effectively address soft atherothrombotic tissue in coronary arteries, vein grafts, and stents.

Purpose of the Study:

  • To assess the clinical safety and efficacy of the X-SIZER catheter for removing soft atherothrombotic tissue.
  • To evaluate the X-SIZER's impact on stenosis reduction and Thrombolysis in Myocardial Infarction (TIMI) flow grade.
  • To analyze angiographic complications, adverse clinical events, and device-related technical failures associated with X-SIZER use.

Main Methods:

  • The X-SIZER catheter was used as an initial device in 85 patients with angiographically suspected thrombus and significant stenosis or TIMI flow reduction.
  • Inclusion criteria included target lesion stenosis >= 70% or >= 50% with TIMI flow reduction and a reference vessel diameter of 3 mm.
  • Outcomes assessed included stenosis reduction, TIMI flow improvement, angiographic complications, adverse clinical events, and technical failures.

Main Results:

  • The X-SIZER catheter successfully reached and activated in the target lesion in 84% of patients (71/85).
  • X-SIZER success, defined by improved TIMI flow or >= 20% stenosis reduction without major adverse clinical events, was achieved in 85% of cases (60/71).
  • Technical failures occurred in tortuous anatomy or vessels < 3 mm; minor complications like thrombus dislodgement (3 patients) and vessel perforation (1 patient) were observed without severe sequelae.

Conclusions:

  • The X-SIZER Catheter System is safe and effective for treating soft atherothrombotic tissue in relatively large, non-tortuous coronary vessels.
  • The device demonstrates significant potential in improving stenosis and TIMI flow, offering a valuable option for challenging thrombotic lesions.
  • Future improvements in catheter design could expand its utility to more complex vascular anatomies.

Related Concept Videos

Acute Coronary Syndrome III: Diagnostic Studies01:30

Acute Coronary Syndrome III: Diagnostic Studies

Diagnosing acute coronary syndrome or ACS begins with a thorough patient history. Notable symptoms include central, crushing chest pain radiating to the left arm, neck, jaw, or back, along with shortness of breath, sweating (diaphoresis), nausea, vomiting, dizziness, and palpitations.It is crucial to note any history of cardiac illnesses and assess risk factors, including age, gender, smoking, hypertension, diabetes, hyperlipidemia, and a sedentary lifestyle.During physical examination, vital...
Venous Thrombosis III: Interprofessional Care01:29

Venous Thrombosis III: Interprofessional Care

Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care01:29

Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care

Diagnosing Pulmonary EmbolismDiagnosing pulmonary embolism (PE) involves clinical assessment and advanced imaging tests. The preferred diagnostic tool is the spiral (helical) CT scan or CT angiography (CTA), which uses intravenous contrast media to visualize the pulmonary vasculature and identify emboli.A ventilation-perfusion (V/Q) scan is an alternative for patients unable to receive contrast media. This scan includes both perfusion and ventilation scanning. Perfusion scanning involves...