Related Experiment Video
Updated: Oct 9, 2026

Pioneering Patient-Specific Approaches for Precision Surgery Using Imaging and Virtual Reality
Published on: April 5, 2024
Prototype of a JAVA/DICOM image server with integrated findings and data security
J Bernarding1, A Thiel, I Decker
1Institute of Medical Informatics, Biostatistics and Epidemiology, University Hospital Benjamin Franklin, Free University Berlin, 12200 Berlin.
Abstract:
The transfer of medical data within heterogeneous hard- and software infrastructures requires platform-independent standardized protocols and data formats such as DICOM. To avoid costly vendor-specific solutions a DICOM server was implemented in JAVA thereby enabling the data access via internet browser technology. The most important patient and image acquisition information were extracted from the DICOM images and stored into a relational database. For an integrated view patient information such as radiological findings were transferred from the Radiological Information System (RIS) into the data base. Image data were accessed either by a fast preview tool or using a DICOM viewer. Since DICOM does not include inherent data security mechanisms, a second tool allowed the DICOM-conform encryption of DCIOM data for a secure long term storage on CD-R or across unsecure networks.
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Integrated Healthcare System
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...