Related Experiment Video
Updated: Aug 15, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast
1Centre for Intelligent Chemical Instrumentation, Department of Chemistry, Ohio University, Athens, OH 45701, USA.
Abstract:
A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...