[Polyethylene content and cell size of foreign body giant cells in aseptic hip prosthesis loosening--a
M von Knoch1, G Plötz, M Prymka
1Orthopädische Universitätsklinik Kiel.
Introduction:
In aseptic loosening of cementless hip arthroplasty polyethylene particles are phagocytized by macrophages and foreign-body giant cells. This initiates an osteolytic cascade. In this study, the authors investigated if there are correlations between the size of foreign-body giant cells and the polyethylene loading and number of intracellular particles as determined by light microscopy.
Material And Method:
Histological specimens were processed from tissues retrieved during revision surgery of 7 cases of cementless hip arthroplasty which had become aseptically loose. The specimens were analyzed by histolomorphology and histomorphometry. The cell size, polyethylene loading and intracellular particle number of 111 foreign-body giant cells were determined. A regression analysis was performed to investigate if there was a correlation between these variables.
Results:
The mean cell size was 1417 +/- 487 micron 2, the mean polyethylene loading was 49 +/- 42 micron 2 and the mean intracellular particle number was 10.4 +/- 5.4. The cell size correlated with both the intracellular particle number (r = 0.25) and the polyethylene loading (r = 0.39).
Conclusions:
In the cellular reaction to polyethylene particles in aseptic loosening of cementless total hip arthroplasty, the size of foreign-body giant cells correlates with intracellular polyethylene loading and intracellular polyethylene particle number as determined by light microscopy. The presence of large foreign body giant cells might be associated with a high particle load of the tissue and a high osteolytic activity.