Updated: Oct 9, 2026

In Vivo Functional Assessment of Rat Masseter Muscle Following Surgical Creation of a Volumetric Muscle Loss (VML) Injury
Published on: November 15, 2024
Immediate effect of occlusal contact pattern in lateral jaw position on the EMG activity in jaw-elevator muscles in
1Graduate School, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549 Japan. k.baba.pro1@dent.tmd.ac.jp
Purpose:
The aim of this study was to investigate the effect of experimental alterations of nonworking-side occlusal contacts on jaw-elevator muscle activity.
Materials And Methods:
Individual devices were fabricated to simulate various lateral occlusal relationships. Twelve human subjects were asked to carry out submaximal lateral clenching, and electromyographic (EMG) activity of the masseter and anterior and posterior temporalis muscles was measured.
Results:
Clenching in a lateral mandibular position under natural conditions induced an activity pattern with a clear dominance of the anterior and posterior temporalis muscles on the working side. Working-side dominance in the anterior temporalis was reduced moderately when an experimental nonworking-side occlusal contact was added. Dominance decreased dramatically when an experimental nonworking-side interference was added. The working-side activity in the posterior temporalis was also reduced dramatically by an experimental nonworking-side interference, but not by a nonworking-side occlusal contact. None of the experimental contact patterns had a significant effect on the masseter activity.
Conclusion:
These results suggest that the nonworking-side occlusal contacts have a significant effect on clenching-induced temporalis muscle activity.
Related Concept Videos
Muscles for Facial Expressions
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Generation of Action Potential in Skeletal Muscles
Like neurons, muscle cells are also regarded as excitable due to their capacity to change in response to stimuli, primarily due to voltage-gated ion channels embedded in their plasma membranes, which get activated by alterations in the cell's...