Analysis of histidine and urocanic acid isomers by reversed-phase high-performance liquid chromatography
1Klinik und Poliklinik für Dermatologie und Allergologie am Biederstein, Technische Universität München, Munich, Germany.
Abstract:
The qualitative separation performance of a C18, C8 and C4 reversed-phase column was investigated for the separation of histidine and its metabolites histamine, 1-methyihistamine and trans- and cis-urocanic acid. Trans- and cis-urocanic acid were baseline separated from their precursor histidine on all three columns using isocratic elution with a mobile phase composed of 0.01 M aqueous TEAP pH 3.0 and acetonitrile at a ratio of 98:2 (v/v). However, histidine was not separated from histamine and 1-methyihistamine. Selecting the C8 column and introducing 0.005 M of the ion pairing reagent 1-octanesulfonic acid sodium salt into the aqueous solution and acetonitrile at a ratio of 90:10 (v/v), significantly improved the separation. The separation was also followed by a change in the retention times and the order of elution. The sequence of elution was histidine, cis-urocanic acid, trans-urocanic acid, histamine and 1-methylhistamine with retention times of 5.58 +/- 0.07, 7.03 +/- 0.15, 7.92 +/- 0.18, 18.77 +/- 0.24 and 20.79 +/- 0.21 min (mean +/- SD; n=5). The separation on the C8 column in the presence of the ion-pairing reagent was further improved with gradient elution that resulted in a reduction in the retention times and elution volumes of histamine and 1-methylhistamine. The detection limits of histidine and trans-urocanic acid at a wavelength of 210 nm and an injection volume of 0.05 ml were 5 x 10(-8) mol l(-1) (n=3). The kinetic of the in-vitro conversion of trans- into the cis-isomer after UV irradiation was depending on the time of exposure and the energy of the light source. UVB light induced a significantly faster conversion than UVA light. TUCA and cUCA samples kept at -25 degrees C were stable for up to 50 weeks. Samples, eluted from human skin showed various concentrations of histidine and trans- and cis-urocanic acid with an average of 1.69 +/- 0.33 x 10(-5) mol l(-1), 1.17 +/- 0.43 x 10(-5) mol l(-1) and 1.67 +/- 0.33 x 10(-5) mol l(-1), respectively (n=8).
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Affinity Chromatography