Related Experiment Video
Updated: Aug 7, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Peripheral arterial vascular function at altitude: sea-level natives versus Himalayan high-altitude natives
A Schneider1, R E Greene, C Keyl
1Department of Anesthesiology, University Medical Centre Regensburg, University of Regensburg, Germany.
Objectives:
Regulation of the vascular system may limit physical performance and contribute to adaptation to high altitude. We evaluated vascular function in 10 Himalayan high-altitude natives and 10 recently acclimatized sea-level natives at an altitude of 5,050 m.
Methods:
We registered electrocardiogram, blood flow velocity in the common femoral artery, and blood pressure in the radial artery using non-invasive methods under baseline conditions, and during maximal vasodilation after 2 min leg occlusion. Vascular mechanics were characterized by estimating pulse wave velocity and input impedance.
Results:
Pulse wave velocity and parameters of input impedance did not differ between groups under baseline conditions. In the post-ischemic period, the ratio between maximal hyperemic and baseline blood flow velocity was significantly higher in the high-altitude than in the sea-level natives (5.7 +/- 2.5 versus 3.8 +/- 1.2, P < 0.05). The leg vascular resistance decreased in the post-occlusive period without differences between groups. Characteristic impedance decreased in the post-ischemic period by about one third of the baseline level without differences between groups. The post-ischemic decrease of input impedance modulus was more marked in the high-altitude than in the sea-level natives at low frequencies (28 +/- 12 versus 6.4 +/- 20% at 2 Hz, P < 0.01).
Conclusions:
Our results demonstrate a superior ability to increase blood flow velocity as a response to muscular ischemia in high-altitude natives compared to sea-level natives. This phenomenon may be associated with a more effective coupling between blood pressure and blood flow which is probably caused by differences in conduit vessel function.
More Related Videos
Related Concept Videos
Factors Affecting Respiration
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease IV: Nursing Management