Related Experiment Video
Updated: Oct 9, 2026

Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
Biodistribution and radiation dosimetry of the dopamine transporter ligand
T A Deterding1, J R Votaw, C K Wang
1Center for PET, Department of Radiology, Emory University Hospital, Atlanta, Georgia, USA.
Unlabelled:
18F-labeled 2 beta-carbomethoxy-3beta-(4-chlorophenyl)-8-(-2-fluoroethyl)nortropane ([18F]FECNT) is a recently developed dopamine transporter ligand with potential applications in patients with Parkinson's disease and cocaine addiction.
Methods:
Estimates of the effective dose equivalent and doses for specific organs were made using biodistribution data from 16 Sprague-Dawley rats and nine rhesus monkeys. PET images from two rhesus monkeys were used to calculate the residence time for the basal ganglia. The computer program MIRDOSE3 was used to calculate the dosimetry according to the methodology recommended by MIRD.
Results:
The basal ganglia were the targeted tissues receiving the highest dose, 0.11 mGy/MBq (0.39 rad/mCi). The effective dose equivalent was 0.018 mSv/MBq (0.065 rem/mCi), and the effective dose was 0.016 mSv/MBq (0.058 rem/mCi).
Conclusion:
Our data show that a 185-MBq (5-mCi) injection of [18F]FECNT leads to an estimated effective dose of 3 mSv (0.3 rem) and an estimated dose to the target organ or tissue of 19.4 mGy (1.93 rad).
More Related Videos
06:18Brain Slice Biotinylation: An Ex Vivo Approach to Measure Region-specific Plasma Membrane Protein Trafficking in Adult Neurons
Published on: April 3, 2014
14:21Creating Dynamic Images of Short-lived Dopamine Fluctuations with lp-ntPET: Dopamine Movies of Cigarette Smoking
Published on: August 6, 2013
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Factors Affecting Drug Distribution: Physiological Barriers
The capillary endothelial barrier allows only smaller molecules below 600 Da (Daltons) to pass through. It also restricts drugs like heparin that are bound to blood components, limiting their movement within the bloodstream.
The...
Tissue-Drug Binding: Localization of Drugs and its Significance
Drugs can bind to different tissue components, enhancing their distribution and localization. The factors influencing drug localization in tissues include the drug's lipophilicity, structural characteristics, tissue perfusion rate, and pH differences. These factors determine the...