Related Experiment Video
Updated: Aug 14, 2026

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Thoracoabdominal aortic repair in a 190-kg patient: optimized perfusion with two oxygenators
E Gygax1, P Schüpbach, T P Carrel
1Clinic for Cardiovascular Surgery, University Hospital, Berne, Switzerland.
Abstract:
A 190-kg patient was referred because of an acute type B aortic dissection. Conservative management was initially performed but the 34-year-old patient was shown to have an increasing aortic diameter 2 months later and was scheduled for elective repair of the thoracoabdominal aorta. To anticipate potential difficulties with perfusion and oxygenation the cardiopulmonary bypass circuit was constructed with two parallel oxygenators, which allowed an adequate oxygen supply through all phases of the intervention and accelerated the estimated rewarming time.