[Doppler color ultrasonography in the diagnosis of erectile dysfunction of vascular origin]
1Servizio di Andrologia, Azienda Ospedaliera San Paolo, Milano. ufuman@tin.it
Abstract:
The aim of this paper is to evaluate whether echo-color Doppler diagnostics allows to detect the different evolutionary stages of arteriopathy affecting the cavernous arteries of the penis. 124 patients with erectile deficiency were examined. All of them were evaluated by andrologic and psychologic anamnesis. An echo-color Doppler examination was performed on cavernous arteries before (basal) and after (dynamic) an injection of Prostaglandin E1 (10 micrograms). The penile circulation has been observed for twenty minutes after the injection to detect anomalous collateral vessels of the cavernous arteries. The population was divided into 4 groups according to the basal and dynamic peak systolic velocity (PSV). Cardiovascular risk factor incidence in patients with normal basal and dynamic PSV values (group A) and in patients with pathologic basal and dynamic PSV values (group C) is 10% and 44% respectively (p < 0.002). Psychologic disorder in group A and C is 41% and 26% respectively (p < 0.05). Patients with pathologic basal PSV and normal dynamic PSV (group B) show an intermediate (26%) incidence of cardiovascular disorders as compared to A and C. Anomalous side branches are equally represented in A and B (41% and 38%) and to a lesser extent in C (26%). Based on anamnestic and instrumental data, Group B ranges at an intermediate position between A and C. In this group, the presence of incipient arteriopathy affecting the penile circulation may be suspected. The ability to detect patients with vascular diseases still at a subclinical stage, as it already happens for other organs, would allow a prompt therapeutic action.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation