Related Experiment Video
Updated: Jul 23, 2026

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
The treatment of trochanteric hip fractures using a compression screw
Abstract:
One hundred and four consecutive intertrochanteric hip fractures treated with a compression screw were reviewed. Despite death and lack of follow-up, the late results in sixty-two cases of fracture were analyzed. Three non-unions and one malunion gave the technique a failure rate of only 6.4 per cent. Twenty-two patients with both stable and unstable fractures were allowed to bear weight as early as tolerated, in an average of fourteen days. Early weight-bearing did not appear to compromise the end result.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024