Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium
J M Boiano1, M E Wallace, W K Sieber
1US Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Cincinnati, OH 45226, USA.
Abstract:
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...