Related Experiment Video
Updated: Oct 9, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
[Assessment of diabetic alterations of microcirculation by means of capillaroscopy and laser-Doppler anemometry]
1Medizinische Klinik, Universitätsklinik Bergmannsheil, Ruhr-Universität Bochum.
Background:
Only minor changes of skin capillary morphology have been described in diabetic patients by means of capillaroscopy, whereas cutaneous microvascular dysfunction is well known. We examined correlations between functional and morphological abnormalities of the capillaries in Type 1 and 2 diabetic patients and the influence of diabetes duration on capillary morphology.
Patients And Methods:
Density, diameters and morphology of nailfold capillaries were investigated in diabetic patients, 16 Type 1 and 19 Type 2, and compared to age- and sex-matched control groups. Capillary blood cell velocities (CBV) during rest and after 3-minute arterial occlusion were measured in the dorsal middle phalangeal area of the left ring finger by means of laser Doppler anemometry.
Results:
Capillary density, width and arterial limb diameter were similar in Type 1 and 2 diabetic patients compared to their controls. Capillary diameters of the apical part and the venous limb were enlarged in the combined analysis of Type 1 and 2 diabetic patients compared to the control group (apex: 19.2 +/- 0.6 microns vs 17.4 +/- 0.6 microns, p = 0.0243; venous limb: 17.3 +/- 0.5 microns vs 15.9 +/- 0.4 microns, p = 0.0238). Tortuous capillaries were more often observed in Type 1 (n = 13 vs n = 7, p = 0.028) and 2 diabetic patients (n = 16 vs n = 9, p = 0.019) than in controls. In Type 1 diabetic patients an inverse correlation (r = -0.52; p = 0.019) was found between capillary density and resting CBV. In Type 2 diabetic patients capillary apex diameter correlated positively with peak CBV (r = 0.49; p = 0.017). Disease duration correlated inversely with arterial limb diameter (r = -0.48; p = 0.020) and width of the capillaries (r = -0.48; p = 0.018) in Type 2 diabetic patients.
Conclusion:
Tortuous and dilated capillaries, indicating microangiopathy, were found in the skin of diabetic patients by means of capillaroscopy. Using laser Doppler anemometry it is possible to assess impairment of postocclusive reactive hyperemia, due to diabetic microvascular dysfunction, in single capillaries. Correlations between morphological and functional microcirculatory alterations in diabetes may be explained by hemodynamic changes, depending on diabetes duration.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Diabetic Retinopathy
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
