Related Experiment Video
Updated: Aug 13, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
High-performance liquid chromatography with electrochemical detection for the determination of
M A El Hassan1, M A Kedde, A Bast
1Department of Medical Oncology, Free University Hospital, Amsterdam, The Netherlands. m.abulhassan@azvu.nl
Abstract:
MonoHER (7-monohydroxyethyl rutoside) is a semisynthetic flavonoid, which can be used as a modulator for doxorubicin-induced cardiotoxicity. To study the pharmacokinetics of monoHER in mice and human an HPLC procedure was developed to measure the level of monoHER in plasma. After extraction of monoHER with methanol, the supernatant was equally diluted (v/v) with 25 mM phosphate buffer (pH 3.33). This solution was analysed by HPLC, using a reversed-phase ODS column, with a mobile phase consisting of 49% methanol and 51% of an aqueous solution containing 10 mM sodium dihydrogen phosphate (pH 3.4), 10 mM acetic acid and 36 microM EDTA. The retention time of monoHER was about 5.2 min. The lower limit of quantification of monoHER was set at 0.3 microM and the calibration line was linear up to 75 microM. The within-day accuracy and precision of the quality control samples (0.45, 1.0, 10 and 40 microM) were better than 15 and 13%, respectively. The between-day accuracy and precision were less than 3, 20%, respectively. The recovery of monoHER (using quality control concentrations) was concentration independent and ranged from 90.5 to 95.3% except for the lowest quality control, 0.45 microM, of which the recovery was 85%. The concentration of monoHER in plasma decreased with 10% when stored at -80 degrees C for one month and with 20% when stored at -20 degrees C for 3 weeks. The repeated injection of monoHER in aliquots of 10 microM, stored in the autosampler tray (4 degrees C), showed a consistent decrease during a run: 15% over 24 h. To compensate for this decrease, sample duplicates were analysed in a mirror image sequence.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...