Magnetic resonance angiography for the evaluation of lower extremity arterial disease: a meta-analysis
Related Experiment Video
Updated: Jun 20, 2026

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
M J Koelemay1, J G Lijmer, J Stoker
1Department of Surgery, G4-111, Academic Medical Center, PO Box 22700, 1100 DE Amsterdam, the Netherlands.
Context:
Magnetic resonance angiography (MRA) is a rapidly evolving technique that has been reported to be accurate for assessment of lower extremity arterial disease.
Objective:
To obtain the best available estimates of the diagnostic performance of MRA in patients with lower extremity arterial disease.
Data Sources:
Studies published from January 1985 through May 2000 in English, German, or French, identified from the MEDLINE, EMBASE, and Current Contents databases.
Study Selection:
Studies were included that allowed construction of 2 x 2 contingency tables for detection of stenosis greater than 50% or occlusion with MRA or arteriography in patients with claudication or critical ischemia.
Data Extraction:
Two observers graded the following elements of study quality: consecutively enrolled patients, prospective study design, clear cut-off levels, blinded assessment, and clear description of MRA technique. Summary receiver operating characteristic analysis was performed to examine the influence of year of publication, all methodological criteria, arterial tract, number of subdivisions within arterial tracts, and MRA technique on diagnostic performance.
Data Synthesis:
Of 3583 studies initially identified, 34 were included that evaluated MRA in 1090 patients (72% men; median age, 65 years). Magnetic resonance angiography was highly accurate for assessment of all lower extremity arteries. Three-dimensional gadolinium-enhanced (3-D Gd) MRA improved diagnostic performance compared with 2-D MRA (relative diagnostic odds ratio, 2.8 [95% confidence interval, 1.2-6.4]), adjusted for number of subdivisions within arterial tracts. The estimated points of equal sensitivity and specificity were 94% and 90% for 3-D Gd MRA and 2-D MRA, respectively.
Conclusions:
Magnetic resonance angiography is highly accurate for assessment of the entire lower extremity for arterial disease. Three-dimensional Gd-enhanced MRA improves diagnostic performance compared with 2-D MRA.
More Related Videos
07:25Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
09:18Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Related Concept Videos
Pulse Assessment Sites
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure in the Leg
Preparation:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies