Abstract:
Pectinesterase (PE) was extracted from orange juice and pulp with 1 M NaCl, desalted, and separated using capillary electrophoresis (CE) gel procedures (CE-SDS-CGE) and isoelectric focusing (CE-IEF). PE resolved as a single peak using noncoated fused silica columns with CE-SDS-CGE. CE-IEF separation of PE required acryloylaminoethoxyethanol-coated columns, which had limited stability. Thermal stability of PE extracts before and after heating at 75 degrees C for 30 min and at 95 degrees C for 5 min established heat labile and heat stabile fractions with identical PE migration times by CE-SDS-CGE or CE-IEF. Peak magnitude decreased to a constant value as heating time increased at 75 degrees C. Regression analysis of CE-SDS-CGE peak migration times of molecular weight (MW) standards estimated both heat labile and heat stable PE at MW approximately 36 900. Traditional SDS-PAGE gel separation of MW standards and active PE isolated by IEF allowed estimation of MW approximately 36 000. CE-SDS-CGE allowed presumptive, but not quantitative, detection of active PE in fresh juice.
More Related Videos
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method
Published on: June 14, 2020
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...