Related Experiment Videos
A Three-Dimensional Finite Element Scheme to Investigate the Apparent Mechanical Properties of Trabecular Bone
RAKESH Saxena1, TONY S. Keller, JOHN M. Sullivan
1Department of Mechanical Engineering, The University of Vermont, Burlington, VT 05405.
Abstract:
A computational technique is described for investigating the apparent mechanical properties of trabecular bone based on tissue geometry obtained from the marching cubes volume rendering scheme. Using this scheme, a 3D representation of the trabecular bone was extracted from two-dimensional cross-sections of the tissue originating from a quantitative serial sectioning procedure. Surface information consists of node coordinates and polygon connectivity in a 3D space. A custom, adaptive mesh generation technique using a normal offset was used to prepare 3D finite element volume meshes (4-node tetrahedral elements) of variable mesh density from the extracted surface geometry. Nine target mesh resolutions (32 µm to 107 µm) were examined for a (1.5 mmx 1.5 mmx 2 mm) volume of trabecular bone. A mesh density of 50,000 elements/mm(3) of bone tissue was found to be adequate for convergence of apparent (bulk) modulus for 1% uniaxial compression. For this convergent case, the maximum local normal compressive tissue stress was 400 MPa which was six hundred-fold greater than the computed apparent stress. Variation in the apparent modulus was less than 5% when Poisson's ratio values were varied between 0.1 and 0.4. Poisson's ratio values greater than 0.4 had a more marked effect on the apparent modulus. Based upon these results, approximately 1 million, 4-node tetrahedral elements are required to analyze a continuum scale model of trabecular bone (5 mm cube).