Patterns of palmar skin temperature alterations during transthoracic endoscopic T2 sympathectomy for palmar
1Department of Neurosurgery, Chang Gung Memorial Hospital, 123 Ta-Pei Road, Niao-Sung Hsiang, Kaohsiung Hsien 833, Taiwan, ROC.
Abstract:
Transthoracic endoscopic T2 sympathectomy has been widely applied to the treatment of a variety of sympathetically mediated disorders. Palmar hyperhidrosis is probably the most common indication for thoracic sympathectomy, especially in certain subtropical areas. Which sympathetic ganglion is to be ablated and how extensive such ablation is enough to eliminate palm sweating are two important issues. Intraoperative monitoring of palmar skin temperature (PST) is the most frequently used method for assessing the accuracy as well as adequacy of ablation of the target sympathetic ganglia. With continuous monitoring of bilateral PST during the operative course of T2 sympathectomy, it was possible to depict the alterations of bilateral PST in response to specific surgical procedures in a real-time manner. For each case, a PST graph was obtained, which represented the graphical expression of intraoperatively recorded bilateral PST data plotted against time. The PST graphs of 93 consecutive cases were analysed. Three types of PST graphs existed, reflecting different responses of bilateral PST to different surgical procedures during the operation. In Type I PST graph pattern, found in 58 cases, skin incision and intercostal muscle dissection caused dramatic bilateral PST drop; and unilateral T2 sympathectomy induced synchronous bilateral PST elevation. Twenty-four cases demonstrated Type II PST graph pattern, in which unilateral T2 sympathectomy caused only ipsilateral PST elevation, although the PST-depressing effect of skin incision and muscle dissection was as significant as in Type I graph pattern. In the 11 cases who showed Type III PST graph pattern, neither skin incision nor T2 sympathectomy induced any apparent changes of PST on either side, giving rise to two rather flat PST curves on the PST graphs. These findings implicate that reciprocal interactions between bilateral sympathetic activities exist in the majority of cases, and that crossover sympathetic modulation may play a role in the neural control of the sudomotor and vasomotor activities of the palms. This study also provides information regarding how PST would possibly change following specific surgical procedures during transthoracic endoscopic T2 sympathectomy, which may be of importance to those who use intraoperative PST monitoring as a guide in determining whether or not the correct sympathetic ganglia are ablated for adequate sympathetic denervation of the palms.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...