Flow Rate Profiler: an instrument to measure blood velocity profiles
Related Experiment Video
Updated: Oct 9, 2026

Micro-particle Image Velocimetry for Velocity Profile Measurements of Micro Blood Flows
Published on: April 25, 2013
R Lombardi1, G Danese, F Leporati
1Dipartimento di Informatica, Università di Pavia, Italian National Institute for the Physics of the Matter. elmedica@ipv36.unipv.it
Abstract:
In this paper we present Flow Rate Profiler (FRP), an instrument for measuring the blood velocity by means of ultrasound-based techniques. The velocity is directly related to the shear rate, which is in turn proportional to the shear stress, a parameter expressing the pressure exerted by the blood on the vessel walls. The knowledge of this value is important in medicine to establish the state of the vessels, directly related to vascular diseases. FRP provides a non-invasive measure of the blood velocity by exploiting the red corpuscles property of diffusing ultrasound waves: in practice blood velocity is determined by a cross-correlation technique, which analyses the time shift between correlated subsequent echo waves, instead of frequency shift characteristic of the Doppler technique. The acquired data are then processed on a personal computer by means of mathematical techniques based on the evaluation of the correlation function, giving a reconstructed velocity profile and showing a good adherence with experimental data, since the average error is nearly the 10%. The reconstructed profile is displayed to the operator, who can follow the vessel status in real time. A few comparisons between the reconstructed and the experimental profiles are also presented, together with a study on a small set of patients suffering from artery hypertension.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Applications of Integration to Find Blood Flow
Pipe Flowrate Measurement: Problem Solving
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Blood Flow