Carotid MR angiography: phase II study of safety and efficacy for MS-325

D A Bluemke1, A E Stillman, K G Bis

  • 1Department of Radiology, Johns Hopkins University School of Medicine, 600 N Wolfe St, Baltimore, MD 21287, USA. dbluemke@rad.jhu.edu

Radiology
|March 29, 2001
PubMed
Abstract

Insights

MS-325 demonstrated high accuracy (88%-100%) for detecting carotid arterial disease via magnetic resonance (MR) angiography. This contrast agent was safe and well-tolerated in patients, showing no severe adverse events.

Area of Science:

  • Radiology
  • Cardiovascular Imaging
  • Medical Diagnostics

Background:

  • Carotid arterial disease poses a significant risk for stroke.
  • Accurate imaging is crucial for diagnosis and treatment planning.
  • Magnetic resonance (MR) angiography offers a non-invasive imaging modality.

Purpose of the Study:

  • To assess the safety and efficacy of MS-325 as a contrast agent for MR angiography.
  • To evaluate MS-325's performance in detecting carotid arterial stenosis.

Main Methods:

  • Twenty-six patients with suspected carotid arterial disease underwent MR angiography.
  • MS-325 was administered intravenously at varying doses (0.01, 0.03, 0.05 mmol/kg).
  • Images were acquired at 5 and 50 minutes post-injection; safety was monitored for 3 days.

Main Results:

  • No severe or serious adverse events were reported with MS-325.
  • At 0.01 and 0.03 mmol/kg, accuracy for detecting >70% stenosis was 100% and 88%, respectively.
  • Higher doses showed decreased sensitivity and specificity.

Conclusions:

  • MS-325 is a safe and effective contrast agent for carotid MR angiography.
  • Optimal accuracy was observed at doses of 0.01 and 0.03 mmol/kg.
  • Steady-state imaging approximately 5 minutes post-injection yielded high diagnostic accuracy.