Resolution and absolute configuration of naturally occurring auronols
Related Experiment Video
Updated: Oct 8, 2026

07:52
A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
R Bekker1, X C Li, H N ElSohly
1Department of Chemistry, University of the Orange Free State, P.O. Box 339, Bloemfontein, 9300 South Africa.
Journal of Natural Products
|March 30, 2001
Abstract:
Resolution of racemic 2-benzyl-2-hydroxy-1-benzofuran-3(2H)-ones (auronols) and CD data of the ensuing enantiomers permit assessment of the absolute configuration at the single stereocenter.
Related Concept Videos
Resonance
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
Resonance and Hybrid Structures
According to the theory of resonance, if two or more Lewis structures with the same arrangement of atoms can be written for a molecule, ion, or radical, the actual distribution of electrons is an average of that shown by the various Lewis structures.Resonance Structures and Resonance HybridsThe Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N–O and N=O bonds.If nitrite ions contain a single and a double bond, the two...
Aromatic Hydrocarbon Anions: Structural Overview
Neutral hydrocarbons like cyclopentadiene with an odd number of carbon atoms and one intervening CH2 group in the ring are not aromatic. Cyclopentadiene with 4 π electrons does not satisfy the 4n + 2 π electron rule. Additionally, the intervening CH2 group is sp3 hybridized and lacks a vacant p orbital, thereby interrupting the overlap of p orbitals in a continuous manner and preventing the delocalization of π electrons throughout the ring.
Due to the absence of continuous overlap of p...
Due to the absence of continuous overlap of p...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Aromatic Hydrocarbon Cations: Structural Overview
Cycloheptatriene is a neutral monocyclic unsaturated hydrocarbon that consists of an odd number of carbon atoms and an intervening sp3 carbon in the ring. The three double bonds in the ring correspond to 6 π electrons, which is a Huckel number, and therefore satisfies the criteria of 4n + 2 π electrons. However, the intervening sp3 carbon disrupts the continuous overlap of p orbitals. As a result, cycloheptatriene is not aromatic.
Removing one hydrogen from the intervening CH2 group with both...
Removing one hydrogen from the intervening CH2 group with both...
High-Resolution Mass Spectrometry (HRMS)
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...