Related Experiment Videos

Changing patterns of airway accidents in intubated ICU patients

F N Kapadia1, K B Bajan, S Singh

  • 1Department of Intensive Care, Hinduja National Hospital & Medical Research Center, Mumbia, India. fkapadia@vsnl.com

Abstract

Insights

Airway accidents in intubated patients shifted, with blocked tracheal tubes now as common as unplanned extubations. This change correlates with increased use of heat and moisture exchanger-filters and improved tracheostomy tube security.

Area of Science:

  • Critical Care Medicine
  • Anesthesiology
  • Respiratory Therapy

Background:

  • Airway accidents are a significant concern in intubated patients.
  • Understanding trends in these accidents is crucial for patient safety.

Purpose of the Study:

  • To document and analyze changes in the patterns of airway accidents among intubated patients over two distinct time periods.
  • To compare the incidence and types of airway accidents between 1994-1997 and 1998-1999.

Main Methods:

  • Prospective recording of all airway accidents in ventilated patients.
  • Comparison of accident data from 1994-1997 (5,046 patients, 9,289 days) with 1998-1999 (2,932 patients, 6,339 days).

Main Results:

  • The overall accident rate decreased from 36 to 20 events.
  • Blocked tracheal tubes became as frequent as unplanned extubations (UE) of endotracheal tubes (ETT), with blocked tubes increasing from 4 to 9 episodes.
  • Tracheostomy tube accidents decreased significantly, becoming similar in frequency to ETT accidents.

Conclusions:

  • A notable shift in airway accident patterns occurred, with a rise in blocked tracheal tubes.
  • Increased use of heat and moisture exchanger-filters is associated with the rise in blocked tracheal tubes.
  • Improved management, including the use of adjustable tracheostomy length tubes, reduced tracheostomy tube displacements.