Related Experiment Video
Updated: Jul 12, 2026

Measuring Cardiac Autonomic Nervous System (ANS) Activity in Children
Published on: April 29, 2013
Within-subject electrocardiographic differences at equal heart rates: role of the autonomic nervous system
J Frederiks1, C A Swenne, J A Kors
1Cardiology Department, Leiden University Medical Center, The Netherlands.
Abstract:
Various combinations of sympathetic and vagal tone can yield the same heart rate, while ventricular electrophysiology differs. To demonstrate this in humans, we studied healthy volunteers in the sitting position with horizontal legs. First, heart rate was increased by lowering the legs to 60 degrees and back. Thereafter, heart rate was increased by handgrip. In each subject, a leg-lowering angle was selected at which heart rate matched best with heart rate in the third handgrip minute. Thirteen subjects had a heart rate match better than 1%. Heart rate (control: 65.2+/-9.0 bpm) increased to 72.1+/-8.7 (leg lowering) and to 72.1+/-8.8 (handgrip) bpm. QRS azimuth, QRS duration, maximal T vector, T azimuth, T elevation, ST duration, QRS-T angle and QT interval differed significantly (P<0.05) between leg lowering and handgrip (QT interval 418+/-15 versus 435+/-21 ms). Also, septal dispersion of repolarization, assessed as the time difference between the apex and the end of the T wave in the V2 and V3 leads, differed significantly (V2: 96.7+/-19.3 versus 110.0+/-23.3 ms, P<0.01; V3: 88.7+/-19.3 versus 97.3+/-23.3 ms; P<0.01). Hence, leg lowering and handgrip cause different ventricular depolarization and repolarization. The hypertensive handgrip manoeuvre entails a longer QT interval and probably an increased septal dispersion of repolarization.
More Related Videos
Related Concept Videos
Regulation of Pulse
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...

