Multicenter experience with the thoratec ventricular assist device in children and adolescents
O Reinhartz1, F M Keith, A El-Banayosy
1University of California at San Francisco Medical Center, San Francisco, California, USA.
Background:
Patient size is 1 determinant in selecting a mechanical circulatory support device. The current pulsatile ventricular assist devices (VADs) were designed primarily for average-sized adults. The flexibility of the Thoratec VAD, however, has encouraged physicians to use it in a significant number of intermediate-sized older children and adolescents.
Methods:
We conducted a retrospective study in 58 children and adolescents <18 years (41 boys, 17 girls) who had been supported with the Thoratec VAD in 27 centers worldwide as of December 1999. Mean patient age was 13.8 years (range, 7 to 17 years), and mean patient weight and body surface area were 51.6 kg (range, 17 to 93 kg) and 1.5 m(2) (range, 0.7 to 2.1 m(2)), respectively.
Results:
Thirty-five patients (60%) survived to transplantation and 6 (10%) to recovery of the native heart, respectively; 38 were discharged from the hospital (66%). In the transplanted group, post-transplantation survival was 97%. Patient age and size were not associated with significantly increased risk for death or adverse events. Fifteen patients (27%) had 18 neurologic events during support, and 6 of these were fatal. Left atrial cannulation proved a risk factor for neurologic complications.
Conclusions:
The Thoratec VAD has successfully been used in a large number of children and adolescents with similar morbidity and mortality results as with adults. The risk of neurologic complications may be increased, particularly in patients cannulated in the left atria.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis III: Medical Management