Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
On the equations describing chromatographic peaks and the problem of the deconvolution of overlapped peaks
P Nikitas1, A Pappa-Louisi, A Papageorgiou
1Department of Chemistry, Aristotle University of Thessaloniki, Greece. nikitas@chem.auth.gr
Abstract:
The problem of the appropriate choice of the function that describes a chromatographic peak is examined in combination with the deconvolution of overlapped peaks by means of the non-linear least-squares method. It is shown that the majority of the functions proposed in the literature to describe chromatographic peaks are not suitable for this purpose. Only the polynomial modified Gaussian function can describe almost every peak but it is mathematically incorrect unless it is redefined properly. Two new functions are proposed and discussed. It is also shown that the deconvolution of an overlapping peak can be done with high accuracy using a non-linear least-squares procedure, like Microsoft Solver, but this target is attained only if we use as fitted parameters the position of the peak maximum and the peak area (or height) of every component in the unresolved chromatographic peak. In case we use as fitted parameters all the parameters that describe each single peak enclosed in the multi-component peak, then Solver leads to better fits, which though do not correspond to the best deconvolution of the peak. Finally, it is found that Solver gives much better results than those of modern methods, like the immune and genetic algorithms.
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Principles Of Column Chromatography