Abstract:
Two methods for the on-line detection in HPLC eluates of analytes possessing radical scavenging activity were improved and compared. The instrumental set-up of the method that is based on on-line inhibition of luminol chemiluminescence (CL) by antioxidants was improved using better quality syringe pumps, employing a diode array detector, and introducing a mixing/neutralisation coil and a pulse damper. Sensitivity of the HPLC-CL detection increased by a factor of 4. Post-column neutralisation of eluates improved compatibility of this detection method with acidified HPLC eluents. The second method, which is based on the post-column quenching of 2,2'-diphenyl-1-picrylhydrazyl radical (DPPH*), was improved by readjusting composition and flow-rate of the reagent, mounting an additional pulse damper and detecting unreacted DPPH* with a detector equipped with a tungsten lamp. Purging of the DPPH* solution with He gas prior to analysis was introduced. This led to 30-fold better detection limits. The improved methods were compared with respect to limits of detection, the radical scavenging mechanism involved, compatibility with common HPLC solvents and pH range, and some technical aspects. The techniques described have high potential for the rapid identification of radical scavengers in complex samples like plant extracts.
More Related Videos
10:30A Generalized Method for Determining Free Soluble Phenolic Acid Composition and Antioxidant Capacity of Cereals and Legumes
Published on: June 10, 2022
07:05Microwave-Assisted Extraction of Phenolic Compounds and Antioxidants for Cosmetic Applications Using Polyol-Based Technology
Published on: August 23, 2024
Related Concept Videos
Principles Of Column Chromatography
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors