Related Experiment Video
Updated: Jul 11, 2026

A Blood-based Test for the Detection of ROS1 and RET Fusion Transcripts from Circulating Ribonucleic Acid Using Digital Polymerase Chain Reaction
Published on: April 5, 2018
The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial
A A Renshaw1, K M Lezon, D C Wilbur
1Department of Pathology, Baptist Hospital of Miami, Miami, Florida, USA.
Background:
Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation.
Methods:
The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology.
Results:
The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low.
Conclusions:
Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.
More Related Videos
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Errors In Hypothesis Tests
Testing a Claim about Population Proportion
There are two methods of testing a claim about a population proportion: (1) Using the sample proportion from the data where a binomial distribution is approximated to the normal distribution and (2) Using the binomial probabilities calculated from the data.
The first method uses normal distribution as an approximation to the binomial distribution. The requirements are as follows: sample size is large...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5% chance...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Receiver Operating Characteristic Plot