Cardiac output measurements in congenital heart disease: validation of a simple, portable Doppler method
T L Gentles1, J M Neutze, A L Caulder
1Department of Cardiology, Green Lane Hospital, Auckland, New Zealand.
Abstract:
Noninvasive Doppler cardiac output measurements are clinical standards in adults and children. Presently, these standard Doppler methods generally require relatively expensive and large imaging equipment with complex signal-processing techniques. Thus, universal access to these important measurements has been limited. Simple, portable Doppler methods have been validated previously and applied to infants and children without cardiac disease. Nevertheless, these specific, inexpensive techniques have not been validated in children with complex congenital heart disease. Accordingly, we compared a noninvasive, suprasternal, non-image-guided, pulsed Doppler cardiac output with standard invasive Fick cardiac outputs in 20 patients (age range, 1 month to 15 years) with congenital heart disease. Doppler cardiac output was displayed by multiplying the mean velocity with an operator-selected angiographic or echographic estimate of the aortic diameter. The values from linear regression analysis were r = 0.96; Doppler cardiac output = 0.98 x Fick cardiac output - 0.08 L/min (range, 0.55-3.10 L/min). The 95% confidence limits were less than 35% of the mean of Doppler and Fick cardiac outputs across the range of measurements. We conclude that relatively linear and accurate measurements of cardiac output can be made by this simple, inexpensive, portable method in selected infants and children with various forms of congenital heart disease.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...