Inactivation of Cryptosporidium parvum oocysts using medium- and low-pressure ultraviolet radiation
S A Craik1, D Weldon, G R Finch
1Department of Civil & Environmental Engineering, University of Alberta, Edmonton, AB, Canada T6G 2M8. scraik@ualberta.ca
Abstract:
The effect of ultraviolet radiation from low- and medium-pressure mercury arc lamps on Cryptosporidium parvum oocysts was studied using a collimated beam apparatus. Experiments were conducted using parasites suspended in both filtered surface water and phosphate buffered laboratory water. Inactivation of oocysts was measured as reduction in infectivity using a CD-1 neonatal mouse model and was found to be a non-linear function of UV dose over the range of germicidal doses tested (0.8-119 mJ/cm2). Oocyst inactivation increased rapidly with UV dose at doses less than 25 mJ/cm2 with two and three log-units inactivation at approximately 10 and 25 mJ/cm2, respectively. The cause of significant leveling-off and tailing in the UV inactivation curve at higher doses was not determined. Maximum measured oocyst inactivation ranged from 3.4 to greater than 4.9 log-units and was dependent on different batches of parasites. Water type and temperature, the concentration of oocysts in the suspension, and the UV irradiance did not have significant impacts on oocyst inactivation. When compared on the basis of germicidal UV dose, the oocysts were equally sensitive to low- and medium-pressure UV radiation. With respect to Cryptosporidium, both low- and medium-pressure ultraviolet radiation are attractive alternatives to conventional chemical disinfection methods in drinking water treatment.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration