Related Experiment Video
Updated: Aug 10, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
The effect of seed anisotrophy on brachytherapy dose distributions using 125I and 103Pd
P Lindsay1, J Battista, J Van Dyk
1Physics Education & Research, London Regional Cancer Centre, Canada. patricia.lindsay@lrcc.on.ca
Abstract:
We have evaluated the effect of the anisotropy of individual seeds on dose distributions for permanent prostate implants using 125I and 103Pd. The dose distributions were calculated for various implants using both the line source and point source calculational formalisms, for two different models of 125I and 103Pd seeds. The dose distributions were compared using cumulative dose volume histograms (DVH) and cumulative difference dose volume histograms (deltaDVH) for the prostate target volume and for the rectum surface. The DVHs could not distinguish between the dose distributions from isotropic and non-isotropic seeds. However, the deltaDVHs were useful in determining the fraction of the target volume for which the difference between the dose distribution for line sources and for point sources exceeded a threshold value. The dose distributions were calculated (1) for all the seeds oriented co-linearly, along either the x-, y-, or z-axis, and (2) for the seeds at randomized orientations, more closely resembling the clinical situation. For all cases, there was a significant difference in the effect of seed anisotropy from the different seed types. For the geometrically simpler test cases with a small number of seeds, the effect of anisotropy on the dose distribution was too large to ignore for any of the seed types investigated. For the idealized pre-plan case, the effect was much smaller. For clinical prostate implants, the calculations done with seeds oriented co-linearly along the z-axis (needle implant axis) were a reasonable approximation for those from simulations of seeds with randomized orientations. Again, the effect of anisotropy varied drastically between different seed models, and also between different clinical cases. However, the effect of anisotropy must be considered in the context of all the other uncertainties in clinical brachytherapy treatments.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022