Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Fitting low ratio compression to people with severe and profound hearing losses
Objective:
In this study, we aimed to determine the extent to which wide dynamic range compression and compression limiting could benefit severely and profoundly hearing-impaired adults.
Design:
Subjects were fitted with multi-memory hearing aids incorporating frequency independent input-controlled compression with a 2:1 compression ratio and output-controlled compression limiting. The input compression threshold (CT) was varied to establish the lowest level that maintained audibility for conversational intensity speech without acoustic feedback oscillation. Where a low (40 to 57 dB SPL) CT was possible, this was compared with a moderate (65 to 74 dB SPL) level. The preferred input compression setting was subsequently compared with linear, compression-limited amplification in the same aids. In the three cases where 2:1 input compression could not be used, because of feedback or loudness insufficiency problems, compression limiting was compared with peak clipping. Field trials were conducted over a 2- or 3-mo period to establish preferences.
Results:
Nine of the 16 subjects preferred the inclusion of the higher level input compression, and one preferred lower level input compression. Four subjects preferred linear, compression-limited amplification, one favored peak clipping, and one could not be satisfied with any of the options provided.
Conclusions:
2:1 input compression was useful, and preferred by 10 of the subjects, but for nine subjects the preferred CT was relatively high. With a group 4-frequency average loss of 87 dB HTL, the results demonstrate that fast-acting, low compression ratio systems can be useful for losses traditionally regarded as the domain of linear amplification.
Related Concept Videos
Hearing
Hearing During Infancy and Toddlerhood
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Impedance Combination
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...