Life-threatening respiratory failure following accidental infusion of polyethylene glycol electrolyte solution into

U Narsinghani1, M Chadha, H C Farrar

  • 1Arkansas Children's Hospital, Little Rock, Arkansas 72202-3591, USA. narsinghaniumeshs@exchange.uams.edu

Insights

Accidental lung infusion of polyethylene glycol electrolyte solution (NuLytely) caused severe lung injury in a pediatric patient. Careful monitoring during nasogastric tube administration is crucial to prevent this life-threatening complication.

Area of Science:

  • Pediatric Gastroenterology
  • Pulmonology
  • Critical Care Medicine

Background:

  • Functional fecal retention is a common cause of encopresis in children, often requiring hospitalization for bowel clearance.
  • Polyethylene glycol electrolyte solution is a safe and effective treatment for encopresis in children over six months old when managed appropriately.
  • Patients with altered mental status or impaired airway reflexes require careful monitoring during bowel clearance therapy.

Observation:

  • An 11-year-old female patient experienced accidental infusion of polyethylene glycol electrolyte solution into her lungs via a nasogastric tube.
  • This complication led to the rapid development of life-threatening acute lung injury.
  • The patient required emergent tracheal intubation, suctioning, and mechanical ventilation due to respiratory failure.

Findings:

  • Accidental pulmonary administration of polyethylene glycol electrolyte solution can cause severe acute lung injury in pediatric patients.
  • Nasogastric tube administration of this solution necessitates vigilant monitoring to prevent airway complications.
  • Prompt respiratory support is critical for managing acute lung injury resulting from accidental pulmonary infusion.

Implications:

  • Healthcare providers must exercise extreme caution when administering polyethylene glycol electrolyte solutions via nasogastric tubes, especially in vulnerable pediatric populations.
  • Enhanced protocols and training are needed to minimize the risk of accidental pulmonary infusion during bowel clearance procedures.
  • This case highlights the importance of careful patient selection and close monitoring to ensure the safe use of polyethylene glycol electrolyte solutions in pediatric encopresis management.

Related Concept Videos

Pneumothorax-I01:26

Pneumothorax-I

A pneumothorax is a condition where air builds up in the space between the lung and the chest wall, causing the lung to collapse. This condition arises when air enters the space between the parietal and visceral pleura, disrupting the negative pressure essential for lung inflation. This can lead to a partial or complete collapse of the lung.
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Acute Respiratory Failure-V01:29

Acute Respiratory Failure-V

The treatment for acute respiratory failure varies based on factors like the underlying cause, overall health, and severity. A collaborative healthcare team is essential for early detection, often through arterial blood gas analysis. Identifying the cause is the primary goal, with treatment strategies adjusted for ventilation/perfusion (V/Q) mismatch, shunting, or diffusion impairment.
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-I01:21

Acute Respiratory Failure-I

Acute respiratory failure is a condition characterized by the inability of the lungs to perform their primary function: gas exchange. This failure leads to insufficient oxygen levels (hypoxemia) in the blood, elevated carbon dioxide levels (hypercapnia), or both, causing critical impairment in organ function.
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-III01:30

Acute Respiratory Failure-III

Hypercapnic respiratory failure, also known as Type 2 or ventilatory respiratory failure, is a severe condition characterized by the body's inability to effectively remove carbon dioxide (CO2) from the bloodstream. It leads to an arterial CO2 pressure (PaCO2) exceeding 45 mmHg and a blood pH above 7.35. This situation indicates that the body's ventilatory demand, or the ventilation needed to maintain normal PaCO2 levels, surpasses its supply or the maximum gas flow achievable without causing...
Acute Respiratory Failure-II01:21

Acute Respiratory Failure-II

Type I Respiratory Failure, or hypoxemic respiratory failure, occurs when the partial pressure of oxygen (PaO2) in arterial blood falls below 60 mmHg while breathing room air without a corresponding increase in arterial carbon dioxide levels (PaCO2). This condition highlights a significant impairment in the lungs' capacity to oxygenate the blood.
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Prevention of Further Absorption of Poison01:14

Prevention of Further Absorption of Poison

In cases of acute poisoning, the primary objective is to prevent further absorption of the toxic substance into the body. Immediate interventions using various decontamination techniques targeting the gastrointestinal (GI) tract can achieve this. Decontamination is crucial to prevent poison from entering the systemic circulation, which involves washing affected areas with water and mild soap and removing contaminated clothing. Once external decontamination is done, attention must be turned to...