Influence of errors in sampling time and in activity measurement on the single sample clearance determination
Related Experiment Video
Updated: Oct 7, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
C De Sadeleer1, A Piepsz, H R Ham
1C.H.U., St. Pierre, Brussels, Belgium. carlos.de.sadeleer@skynet.be
Introduction:
Plasma clearance rate of 51Cr-EDTA estimated by using one blood sample is commonly used for the calculation of glomerular filtration rate.
Aim:
To estimate the error on single-sample clearance determination induced by errors in sampling time and activity measurement, and to compare it with the error observed on the clearance determination obtained using the slope-intercept method.
Methods:
Forty-five adult patients were chosen from a data base of 51Cr-EDTA plasma clearance values determined by using two blood samples taken around 2 and 4 h. Patients were selected in such a way as to include clearances from 30 ml.min-1 to 155 ml.min-1, with steps of 3 ml.min-1. Based on the slope and the intercept of the slope with the y-axis, the plasma concentration at exactly 2 and 4 h was determined. Normally distributed random errors were then introduced in the sampling time (SD of 0, 1 and 2 min) as well as in the activity measurement (SD of 0, 1, 2 and 5%). Then, clearance was calculated using two single-sample methods (i.e. the algorithms of Groth and Tauxe), and the slope-intercept method, which requires two blood samples. For each setting, the simulation was repeated 200 times. The effects on clearance of a random error on the time sampling and/or the activity measurement were then evaluated.
Results:
The error on single-sample clearance induced by a 2 min error in sampling time associated with a 5% error in activity measurement was negligible. For all clearance levels, the SD of the error on the calculated clearance was less than 3.8 ml.min-1. Whatever algorithm was chosen, the errors on the single-sample clearance were systematically lower than those observed with the slope-intercept method, for the whole clearance range.
Conclusion:
Errors in sampling time and in activity measurement induced only a very small error on the single-sample EDTA clearance, which is systematically lower compared to that observed on the slope-intercept method using two blood samples.
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Uncertainty in Measurement: Accuracy and Precision
Random and Systematic Errors
Random and Systematic Errors
Errors and Mistakes in Surveying