Abstract:
Late responsive DDD pacemakers are the most technically advanced devices presently available. These pacemakers are particularly useful in patients with chronotropic insufficiency when the sinus node is incapable of accelerating during exercise. The latest pacemakers have two sensors to reproduce optimal physiological sinus acceleration. The aim of this study was to analyse the performances of a new rate responsive pacemaker with a double activity and respiratory sensor, the interaction of which is automatically controlled by a sophisticated algorithm, in 12 patients (8 men and 4 women) with a mean age of 75 +/- 7 years. Analysis was based on the performance of the sensors used singly or in association: during three exercise stress tests with measurement of the VO2 max; during everyday activities using the data archived by the pacemaker and the answers to a simplified questionnaire on quality of life. The results showed that during exercise stress testing with measurement of VO2 max, the best performances were obtained with the double sensor or the respiratory sensor compared with the activity sensor alone, suggesting that these two sensors are more effective in intense exercise. This tendency was also observed in the analysis of the memory bank of the pacemaker which showed that the total duration of the faster heart rates was greater with the two sensors. On the other hand, the quality of life was not significantly different, whichever sensor was studied. Longer scale trials are necessary to appreciate the real value of these new double sensor pacing devices and to identify the best indications for their usage.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...