Molar mass profiling of synthetic polymers by free-solution capillary electrophoresis of DNA-polymer conjugates
W N Vreeland1, C Desruisseaux, A E Karger
1Department of Chemical Engineering, Northwestern University, Evanston, Illinois 60208, USA.
Abstract:
The molar mass distribution of a polymer sample is a critical determinant of its material properties and is generally analyzed by gel permeation chromatography or more recently, by MALDI-TOF mass spectrometry. We describe here a novel method for the determination of the degree of polymerization of polydisperse, uncharged, water-soluble polymers (e.g., poly(ethylene glycol) (PEG)), based upon single-monomer resolution of DNA-polymer conjugates by free-solution capillary electrophoresis. This is accomplished by end-on covalent conjugation of a polydisperse, uncharged polymer sample (PEG) to a monodisperse, fluorescently labeled DNA oligomer, followed by electrophoretic analysis. The monodisperse, charged DNA "engine" confers to each conjugate an equal amount of electromotive force, while the varying contour lengths of the uncharged, polydisperse polymers engender different amounts of hydrodynamic drag. The balance of electromotive and hydrodynamic forces enables rapid, high-resolution separation of the DNA-polymer conjugates as a function of the size of the uncharged PEG tail. This provides a profile of the molar mass distribution of the original polymer sample that can be detected by laser-induced fluorescence through excitation of the dye-labeled DNA. We call this method free solution conjugate electrophoresis (FSCE). Theory-based analysis of the resulting electrophoresis data allows precise calculation of the degree of polymerization of the PEG portion of each conjugate molecule. Knowledge of the molecular mass of the uncharged polymer's repeat unit allows for direct calculation of the molar mass averages as well as sample polydispersity index. The results of these analyses are strikingly reminiscent of MALDI-TOF spectra taken of the same PEG samples. PEG samples of 3.4-, 5-, and 20-kDa nominal average molar mass were analyzed by FSCE and MALDI-TOF; the values of the molar mass averages, Mw and Mn, typically agree to within 5%. Measurements and molar mass calculations are performed without any internal standards or calibration. Moreover, when DNA-polymer conjugate analysis is performed in a chip-based electrophoresis system, separation is complete in less than 13 min. FSCE offers an alternative to MALDI-TOF for the characterization of uncharged, water-soluble polymers that can be uniquely conjugated to DNA.
More Related Videos
06:16MALDI-ToF MS Method for the Characterization of Synthetic Polymers with Varying Dispersity and End Groups
Published on: October 3, 2025
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Determination of Molar Masses of Polymers II
Determination of Molar Masses of Polymers I
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...