Related Experiment Video
Updated: Jul 31, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Evaluation of oxygen extraction ratio as a physiologic transfusion trigger in coronary artery bypass graft surgery
L R Sehgal1, L P Zebala, I Takagi
1Department of Surgery, Evanston Northwestern Healthcare, Chicago, Illinois, USA. lakshmansehgal@hotmail.com
Background:
Approximately 20 percent of all allogeneic blood transfusions are administered in connection with coronary artery bypass graft (CABG) operations. Transfusion practices vary across the country. The whole-body oxygen extraction ratio (O2 ER) reflects the adequacy of the patient's response to acute normovolemic anemia with an O2 ER of approximately 50 percent being shown to be an appropriate transfusion trigger. The present study monitored the O2 ER in patients undergoing CABG and determined if transfusion practices would have been different if an O2 ER > or = 45 percent were used as a transfusion trigger.
Study Design And Methods:
Seventy patients with a postoperative Hct < = 25 percent were the test subjects. Arterial and mixed venous contents were determined before the operation, in the intensive care unit after the operation, and 12 hours after the operation.
Results:
There were no deaths. Forty-one patients received allogeneic transfusion. These patients were older, weighed less, and had a preoperative Hct lower than the nontransfused patients. There were no significant differences between transfused and nontransfused patients with respect to postoperative Hct (21.0 +/- 0.4 vs. 22.2 +/- 0.4), cardiac index (2.5 +/- 0.1 vs. 2.7 +/- 0.1), O2 delivery (6.4 +/- 0.3 vs. 6.7 +/- 0.3), O2 consumption (2.5 +/- 0.1 vs. 2.5 +/- 0.1), and O2 ER (38.3 +/- 1.7 vs. 37.5 +/- 1.5). In the transfusion group, 7 of 21 patients had a postoperative O2 ER > or = 45 percent, while 3 of 35 in the nontransfused group had that result.
Conclusion:
The use of O2 ER as a transfusion trigger as part of a transfusion algorithm could lead to a reduction in allogeneic blood transfusion.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Transport in the Blood