Related Experiment Video
Updated: Aug 4, 2026

Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
The Potential of F-18-FDG PET in Breast Cancer. Detection of Primary Lesions, Axillary Lymph Node Metastases, or
K F. Hubner1, G T. Smith, J A. Thie
1Department of Radiology, University of Tennessee Medical Center, Knoxville, TN, USA
Abstract:
This retrospective study was done to evaluate the utility of 2-[F-18]fluoro-2-deoxy-D-glucose positron emission tomography (F-18-FDG PET) in identifying primary and recurrent breast cancer and lymph node metastases. One hundred whole-body PET scans of 87 patients were reviewed. PET results obtained with F-18-FDG and an ECAT/EXACT-921 or an ECAT-931 (Siemens/CTI) were based on visual interpretation, or standardized uptake values (SUVs), related to histology and also compared to computerized tomography (CT) and mammography results. The sensitivity for PET in detecting primary (N = 35 studies) and recurrent breast cancer (N = 65 studies) was 96% and 85% with a specificity of 91% and 73%. The sensitivity for lymph node metastases at the time of initial diagnosis was 100% with a specificity of 100%. Quantitative SUV information did not improve the accuracy of F-18-FDG PET in identifying primary breast cancers. The results suggest that whole-body PET is useful in detecting recurrence or metastases, may be useful in detecting lymph node metastases prior to initial axillary lymph node dissection, but is less sensitive in excluding axillary lymph nodes metastases later in the course of the disease.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
10:33Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET